MaxSHOT 3D Benefits
- Dimensional measurements that are even more precise
- Increased accuracy in Creaform technologies thanks to photogrammetry
- Very simple to operate
- Real-time visualization and validation of acquired data
- Step-by-step operation entirely guided by the VXshot module
- Ergonomic design
- Shorter measuring time on larger parts
- Accelerated positioning of the Creaform 3D scanner or optical CMM around the part
- Light and portable
The MaxSHOT 3D coordinate measuring system comes with VXelements and the VXshot module, a fully-integrated 3D data acquisition software that powers its entire fleet of 3D scanning and measurement technologies. It gathers all the essential elements and tools into a uniform, user-friendly and intuitive working environment.
VXshot
Unlike other systems on the market, where data accuracy is partially contingent upon the operator’s experience and technique, VXshot features an extremely simple data acquisition process.
- Guides operators every step of the way throughout the process;
- Clearly and immediately notifies operators if they need to take additional pictures to increase measurement accuracy;
- Real-time visualization and validation of the positioning model make it possible to see the rebuilt volume and all estimated points with the utmost accuracy;
- Measures and recomputes all the identified points each time an image is taken.
VXremote: Remote Access Software Application
VXremote improves your efficiency in the field by providing fast and easy remote access to VXelements. It offers quick activation and set-up and requires no hardware or server to install or maintain. You can have all its data acquisition functionalities at your fingertips. Available only with the Creaform Certified Rugged Tablet!
Inspection
- Part-to-CAD analysis
- First article and supplier quality inspection
- Large-scale tooling inspection and adjustment
- Large castings inspection
- Large moulds/dies design or inspection
- Conformity assessment of 3D models against original parts/production tooling
- Conformity assessment of manufactured parts against originals
- Large part alignment
- Full free-form inspection and generation of high density colour maps
Reverse Engineering
- Reverse engineering of geometric entities (spheres, cylinders, planes)
- Allows faster and more accurate reverse engineering of mixed parts (geometrical and free-form)
- Aerospace
- Automotive/Transport
- Consumer Products
- Heavy Industries
- Manufacturing
- Power Generation
- Research and Education
Optical Probing Accessories
Use your MaxShot 3D as an optical probing device and get direct 3D measurements for various types of features: hole location, edge location, surface points, etc.
|
MaxSHOT Next™ |
MaxSHOT Next™|Elite |
Volumetric accuracy (1) |
0.025 mm/m (0.0003 in/ft) |
0.015 mm/m (0.00018 in/ft) |
Average deviation (2) |
0.008 mm/m (0.0001 in/ft) |
0.005 mm/m (0.00006 in/ft) |
Volumetric accuracy (when combined with) |
HandySCAN 307™(3)
HandySCAN BLACK™(3)
HandySCAN BLACK|Elite™(3) |
0.020 mm + 0.025 mm/m
(0.0008 in + 0.0003 in/ft) |
0.020 mm + 0.015 mm/m
(0.0008 in + 0.00018 in/ft) |
Go!SCAN SPARK™(4) |
0.060 mm + 0.025 mm/m
(0.0024 in + 0.0003 in/ft) |
0.060 mm + 0.015 mm/m
(0.0024 in + 0.00018 in/ft) |
HandyPROBE Next™ (5)
MetraSCAN 357™ (5)
MetraSCAN BLACK™ (5) |
0.060 mm + 0.025 mm/m
(0.0024 in + 0.0003 in/ft) |
0.060 mm + 0.015 mm/m
(0.0024 in + 0.00018 in/ft) |
MetraSCAN BLACK™|Elite(5)
HandyPROBE Next™|Elite (5) |
0.044 mm + 0.025 mm/m
(0.0017 in + 0.0003 in/ft) |
0.044 mm + 0.015 mm/m
(0.0017 in + 0.00018 in/ft) |
|
|
|
Weight |
0.79 kg (1.75 lb) |
Dimensions |
104 x 180 x 115 mm (4.1 x 7.1 x 4.5 in) |
Operating temperature range |
5-40°C (41-104°F) |
Operating humidity range (non-condensing) |
10-90% |
Certifications |
EC Compliance (Electromagnetic Compatibility Directive, Low Voltage Directive), IP50, WEEE, Laser class (2M) |
(1) Based on the VDI/VDE 2634 part 1 standard. Performance is assessed with 35 lengths measurements taken on traceable artefacts (value = maximum deviation).
(2) Based on the VDI/VDE 2634 part 1 standard. Performance is assessed with 35 lengths measurements taken on traceable artefacts (value = average deviation).
(3) The volumetric accuracy performance of the system when using a MaxSHOT 3D cannot be superior to the default accuracy performance for a given model.
(4) The volumetric accuracy performance of the system when using a MaxSHOT 3D cannot be superior to the default accuracy
(5) The volumetric accuracy performance of the system when using a MaxSHOT 3D cannot be superior to the default volumetric accuracy performance for a given model.