Dimension 1200 Loss of Extrusion and Tip Replacement

EmailFacebookLinkedInTwitterShare

There are times when your printer may experience a loss of extrusion condition. The print head may be moving with no material coming out of one or both of the tips. To diagnose and recover from a loss of extrusion condition go into Maintenance Mode. Press Maintenance-Machine-Head The head will move to the center of the chamber. The display will read Model Drive Motor Stopped. Press Forward and the drive motor should start turning. It may take up to 30 seconds […]

Read More

Stratasys F123 Series Tip Wipe Assemblies

EmailFacebookLinkedInTwitterShare

It is important to keep the tip wipe assemblies in your Stratasys F Series printer working properly. If the tip wipe assemblies are not cleaning the tips properly, bad print results can occur. The tip wipe assemblies should be checked and cleaned on a monthly basis or anytime you are having print quality issues that may be related to a print head. You should also check the tip wipe assembly any time you notice that material stays stuck to the […]

Read More

How To: Preventative Maintenance DIY Guide for your Stratasys FDM System

EmailFacebookLinkedInTwitterShare

If you have a Stratasys Dimension 1200, Dimension Elite, uPrint, or Fortus 250mc, then doing preventative maintenance is a simple process that can be done on your own. You will first need to obtain a preventative maintenance kit from Stratasys by ordering it through your local reseller. Once the kit arrives you will notice that it contains 4 chamber fans, (2 for uPrint), a head cooling fan, and some covers for the print head. We do not replace the head […]